<LOGO>
FM Transmitter Measurement Report
Created: 2023-08-06 18-08-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 58 dBuV EUROPE 1
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
2 kHz 72 kHz 1000 0,0000
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
2,1 dBr 3,86 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 104.60 MHz, signal: 5/5 (58 dBuV) Max at: 72 kHz MIN: 2 kHz % above 75 kHz: 0,0000 Acquired: 2023/08/06 17:53:45 Total samples: 1000 Equivalent time: 0:00:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 4,8 dBr MIN: 2,1 dBr AVE: 3,85 dBr % above 9,0 dBr: 0,0 Last value: 2,4 dBr (2023/08/06 18:05:08) Station: 104.60 MHz, signal: 5/5 (58 dBuV) 17:54 17:56 17:58 18:00 18:02 18:04 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality